CMS-8000 ( 12.1'' )

CMS-8000 ( 12.1'' )

Non-returnable
Price: On Request
Quantity

Add to Cart

Product Details

Features:

  • Suitable for adult, pediatric and neonatal patients
  • 12.1'' TFT color LCD
  • Parameters: ECG, NIBP, SpO2, Pulse Rate, Respiration, Temperature and IBP (upgradable)
  • Maximum 8-channel waveform synchronous display
  • Graphic and tabular trends for 96 hours for all formats
  • Multi-screen format
  • Powerful data management and storage capacity, 500 NIBP measurement data can be storage and recall
  • AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring
  • Visual and Audio alarms, adjustable.
  • Measurement Mode: Manual/Auto/Stat
  • Warranty: 1 year

 

Specifications:

ECG:

  • 5 lead or 12 lead selectable
  • Input: 5 lead; RA, LT, RL, LL, V or R, L, N, F, C
  • Lead selection: I, II, III, aVR, aVL, aVF, Vx, CAL
  • Gain Selection: ×25, ×0.5, ×1, ×2, auto
  • Sweep speed: 12.5mm/s, 25mm/s, 50mm/s
  • Accuracy: ±1bpm or ±1% whichever is grater
  • Protection: Withstand 4000V AC/50Hz voltage in isolation against electrosurgical and defibrillation
  • Calibration signal: 1mV±5%
  • Operation modes, Diagnostic, Monitor, Surgery
  • Heart rate range: Adult: 15-3000bpm; Pediatric/Neonatal: 15-350bpm
  • Measurement range: -2.0mV to 2.0mV
  • ST detection: YES,
  • Arrhythmia analysis: YES
  • Alarm: YES, audible and visual alarm, alarm events recallable.

 NIBP:

  • Method: Oscillometry
  • Mode: Manual/Auto/STAT
  • Measurement Range: adult 10-270mmHg
  • Measurement Type: Systolic, Diastolic, Mean
  • Resolution: 1mmHg
  • NIBP Accuracy: Mean ±5mmHg, SD ±8mmHg
  • Alarm: SYS/DIA/MEAN

Respiration:

  • Method: RA-LL impedance
  • Measurement range: Adult: 0-120rpm, Paediatric/Neonatal: 0-150rpm
  • Apnea Alarm: YES

SpO2:

  • Measurement range: 0%-100%
  • Accuracy: ±2% (70%-100%); 0%-69% unspecified.
  • Alarm range: 0-100%

 Pulse Rate:

  • Measurement range: 10 - 270
  • Resolution: 1bpm
  • Accuracy: ±2pm or ±2%

Temperature:

  • Resolution: 0.2 0C
  • Channel: Dual-channel
  • Measurement range: 0-50 0C

IBP (Upgradable):

  • Channel: 2
  • Pressure transducer: Sensitivity: 5(mV/V/mmHg)
  • Transducer sites: ART, PA, CVP, RAP, LAP, ICP
  • Alarm range: -10 to 300 mmHg

 

Other Specifications:

  • Net Weight: 3.9kg

 Content of the box:

  • Monitor
  • Power connector
  • Adult/Neonatal cuff + cable (based on selection)
  • ECG leads
  • SpO2 probe
  • Temperature probe
  • User manual